Communication Channels Frequency Range |
For the Upper Side Band: < 2,000–40,000 Hz
For the Lower Side Band: < 5,000–43,000 Hz |
Selection of Modulation Type |
Lower and Upper Side Bands |
Adjustable Number of Channels |
3–6 Channels: Channel frequencies according to NATO (8,087.5 Hz), Turkish (3,500 Hz) or user settings, or others that can be added or adjusted by the user. |
Emergency Channel Interception Frequency Range |
2.000-45.000 Hz |
Emergency Channel Interception (Pinger) Frequency |
The adjustable frequency range of 3–12
- 5,000 Hz 50 ms signal duration, 10 sec. periods
- 35,000 Hz 10 ms signal duration, 1 sec. periods
- User adjustment
- Emergency Channel (pinger) frequencies added and adjusted by the user
|
Distance Measurement Modes |
Fully automatic (TB-SH 05) distance measurement
Semi-automatic (other underwater telephones) distance measurement |
Maximum Distance Measurement Range |
30.000 m |
Characteristics of Telegraph Mode |
- Sending Messages in Morse code: 5–200 word/min.
- Listening to Messages in Morse Code: 5–200 word/min. automatically adjusted
- Receiving and sending Turkish characters according to the ISO 8859-9 standard.
- Transfer messages to the SD/MMC card.
|
Listening and Recording Audio |
- Format: Digital
- Time: 24+ hours
- Maximum Number of Records 1,024 records
- Transfer to the SD/MMC card in a WAV file format
- Sort by date and record length in ascending or descending order
- Listening to audio recordings from all units simultaneously
- Record demodulated signal received from the microphone when transmitting, and from transducer when listening
|
Adjustable Factory-Level Power Output |
10 W (Near), 50 W (Middle), 100 W (Distant) |
Built-in Test Module |
- Online/Offline tests
- Interface tests
- Error/data logging (max. 2,048 items)
- Transferring error/data logs to SD/MMC card in a text file format
|
Interfaces |
ASaCS/SONAR Interface, internal communications interface (optional) |
Operating Voltage |
220 V AC 50 Hz / 115 VAC 50/60 Hz |
Maximum Power Required |
Less than 300 W |
Dehumidification Heater |
Less than 10 W |
Applied Standards |
STANAG 1074, STANAG 1382 |
Environmental Compatibility |
- Operating Temperature Range: 0°C – 45°C
- Storage Temperature Range: -40°C – +70°C
- EMC/EMI Compliance: MIL-STD-461E (RE101, RE102, CE102, RS103, CS101, CS114, CS116, RS101)
- Humidity MIL-STD-810F, %90RH (45°C)
- Vibration: MIL-STD-167-1 standard TYPE-I
- Low and High-Pressure Operation Range: MIL-STD-810F (450 hPa ~ 1.400 hPa)
- Low and High-Pressure Storage Range: MIL-STD-810F (200 hPa ~ 1.400 hPa)
- IP Protection IP23
|